Skip to content
SeaGOAT Electronics logo

Opto-Electronic Test Instruments

Optical spectrum, tunable laser and lightwave component analysis

3 product families

3 instrument families

  • 6433F lightwave component analyzer with optical test unit, front view
    Opto-Electronic Test InstrumentsBenchtop

    6433 Series Lightwave Component Analyzer

    6433D/F/H/L/N/P · 6 models

    Lightwave component analyzers combining a VNA with optical transmitter and receiver modules for E/E, E/O, O/E and O/O measurements from 10 MHz up to 110 GHz.

    Frequency
    10 MHz – 110 GHz
    View details
  • 6317A tunable laser source, front view
    Opto-Electronic Test InstrumentsBenchtop

    6317A Tunable Laser Source

    6317A

    Mode-hop-free Littman external-cavity tunable laser for 1500 nm – 1600 nm (extendable to 1480 nm – 1680 nm), with ±5 pm absolute accuracy and sweeps up to 240 nm/s.

    Wavelength
    1480 – 1680 nm
    Max. output
    +13 dBm
    View details
  • 6362D optical spectrum analyzer, front view
    Opto-Electronic Test InstrumentsBenchtop

    6362 Series Optical Spectrum Analyzer

    6362C/D/E/EA · 4 models

    Benchtop optical spectrum analyzers with 20 pm minimum resolution bandwidth, covering 350 nm – 2500 nm across four models, for laser, WDM and optical amplifier testing.

    Wavelength
    350 – 2500 nm
    View details

About Opto-Electronic Test Instruments

Photonic devices need their own measurement tools. An optical spectrum analyzer (OSA) measures optical power versus wavelength, used to check laser linewidth and side-mode suppression, WDM channel power and spacing, and amplifier gain. A tunable laser source sweeps a precise wavelength to measure wavelength-dependent loss in filters, gratings and passive components. A lightwave component analyzer (LCA) extends VNA techniques to electro-optical devices, measuring the modulation response of lasers, modulators and photodetectors.

The 6362 OSA family covers 350 nm to 2500 nm across four models, with wavelength resolution settings from 0.02 nm and power linearity up to ±0.05 dB. The 6317A tunable laser covers 1500–1600 nm with ±20 pm absolute wavelength accuracy and continuous sweeps from 1 to 200 nm/s. The 6433 LCA spans 10 MHz up to 20, 43.5, 50, 67, 90 or 110 GHz and supports E/E, E/O, O/E and O/O test modes, with balanced device testing and automatic fixture removal.

How to choose

  1. 01

    Wavelength range

    Telecom work centers on 1260–1675 nm, which the 6362D (600–1700 nm) covers. Visible and near-infrared sources, sensing lasers and 2 µm devices call for the 6362C (350–1200 nm) or the 6362E and 6362EA, which extend to 2400 and 2500 nm.

  2. 02

    Resolution and accuracy

    Narrow resolution bandwidth separates closely spaced WDM channels and side modes; wavelength accuracy matters for grid compliance and filter edges. Compare the resolution settings, wavelength accuracy and power linearity at the wavelengths you use.

  3. 03

    Modulation bandwidth for E/O and O/E devices

    For high-speed lasers, modulators and photodiodes, the LCA frequency range must exceed the device's 3 dB bandwidth. Devices for 100G-per-lane and faster links often need 50 GHz or more, which is why the 6433 is offered up to 110 GHz.

Frequently asked questions

Request a Consultation

What does a lightwave component analyzer measure that a VNA cannot?

A VNA has electrical ports only. An LCA adds calibrated optical transmitters and receivers so that it can measure the electrical-to-optical response of a laser or modulator, the optical-to-electrical response of a photodiode, and optical-to-optical transfer, all with magnitude and phase. Calibration removes the response of the LCA's own optical parts, leaving the device's characteristics.

Which OSA model fits telecom work in the C and L bands?

The C band (about 1530–1565 nm) and L band (about 1565–1625 nm) both fall within the 6362D's 600–1700 nm range, which also covers the O band around 1310 nm. If you also characterize sources beyond 1700 nm, consider the 6362E or 6362EA instead.

How do I request a quotation for optical test equipment?

Use the contact form to describe the devices you test, wavelength range, required resolution or modulation bandwidth, fiber connector types, quantity and destination country. SeaGOAT's sales team reviews the request and replies with a quotation or with questions to confirm the right model and configuration.