Skip to content
SeaGOAT Electronics logo
6362D optical spectrum analyzer, front view
Opto-Electronic Test InstrumentsBenchtop

6362 Series Optical Spectrum Analyzer

Model
6362C/D/E/EA
Supplied by
SeaGOAT Electronics
Wavelength
350 – 2500 nm

Benchtop optical spectrum analyzers with 20 pm minimum resolution bandwidth, covering 350 nm – 2500 nm across four models, for laser, WDM and optical amplifier testing.

Key highlights

  • 20 pm minimum resolution bandwidth (0.02 nm setting)
  • Up to 73 dB dynamic range (6362D, 0.05 nm resolution)
  • Sensitivity down to -90 dBm (6362D, 1300 nm – 1620 nm)
  • ±0.02 nm wavelength accuracy in the C/L band on the 6362D
  • Built-in DFB, FP, LED, WDM, EDFA and PMD analysis functions

Supplied by SeaGOAT Electronics, an independent international supplier of electronic test and measurement equipment. SeaGOAT Electronics does not manufacture this equipment; it is sourced through our manufacturing and supply partners.

Specifications

Wavelength
Wavelength range (6362C / 6362D)6362C: 350 nm – 1200 nm 6362D: 600 nm – 1700 nm
Wavelength range (6362E / 6362EA)6362E: 1200 nm – 2400 nm 6362EA: 1000 nm – 2500 nm† Value from the SeaGOAT catalog. Manufacturer confirmation pending.
Span setting range (6362D)0.2 nm – 1100 nm (full span)
Wavelength accuracy (6362D)±0.02 nm (1520 nm – 1620 nm) ±0.04 nm (1450 nm – 1520 nm) ±0.10 nm (full range) ±10 pm (1520 nm – 1580 nm) with 6362D-S02 high-accuracy software
Wavelength accuracy (6362C)±0.200 nm
Wavelength linearity (6362D)±0.015 nm (1520 nm – 1580 nm)
Wavelength repeatability (6362D)±0.005 nm (1 min)
Resolution bandwidth settings (6362C / 6362D)0.02, 0.05, 0.1, 0.2, 0.5, 1, 2 nm
Minimum sampling resolution0.001 nm
Sampling points101 – 50001, AUTO
Optical power
Sensitivity (6362D, HIGH3)-90 dBm (1300 nm – 1620 nm) -85 dBm (1000 nm – 1300 nm) -60 dBm (600 nm – 1000 nm)
Sensitivity (6362C, HIGH3)-60 dBm
Sensitivity settingsNORMAL, MID, HIGH1, HIGH2, HIGH3
Maximum input power (6362D)+20 dBm (per channel, full wavelength range)
Maximum safe input power (6362D)+25 dBm (total input power)
Power accuracy6362D: ±0.4 dB (1310 nm / 1550 nm, -20 dBm ≤ input ≤ 10 dBm, sensitivity MID) 6362C: ±1.0 dB (850 nm, -20 dBm ≤ input ≤ 10 dBm, sensitivity MID)
Power linearity (6362D)±0.05 dB (input -50 dBm – +10 dBm)
Power flatness (6362D)±0.1 dB (1520 nm – 1580 nm) ±0.2 dB (1450 nm – 1520 nm, 1580 nm – 1620 nm)
Polarization dependence (6362D)±0.08 dB (1550 nm, resolution ≥ 0.05 nm)
Dynamic range
Dynamic range (6362D)0.02 nm resolution: 52 dB (peak ±0.2 nm), 32 dB (peak ±0.1 nm) 0.05 nm resolution: 73 dB (peak ±1.0 nm), 58 dB (peak ±0.4 nm), 45 dB (peak ±0.2 nm) 0.1 nm resolution: 55 dB (peak ±0.4 nm), 40 dB (peak ±0.2 nm)
Dynamic range (6362C)60 dB (633 nm, peak ±0.5 nm, 0.02 nm resolution)
Stray light suppression (6362D)76 dB
Optical return loss (6362D)35 dB (with APC connector)
Functions
Applicable fiberSM (9.5/125 µm), GI (50/125 µm, 62.5/125 µm), large-core fiber up to 200 µm (6362D) or 800 µm (6362C)
Built-in light source (6362D)Factory DFB source (1550 ±5 nm); optional SLED (≥ 1 mW, 1550 nm) or SLED + C2H2 absorption cell (6362D-H02 / -H03)
Analysis functions (6362D)DFB-LD (threshold, SMSR), FP-LD (n dB loss, envelope, RMS), LED, LD module, WDM, optical amplifier, WDM filter, fiber PMD; free-space optical input supported
Interfaces and display
Display12.1-inch touch screen
Storage128 GB
Interfaces6362D: USB, Ethernet, VGA 6362C: USB, Ethernet Optional: GPIB, trigger in, trigger out
Physical and environmental
Dimensions (W × H × D)426 mm × 221 mm × 450 mm
WeightApprox. 20 kg
Power supply100 VAC – 240 VAC, 50 Hz/60 Hz
Maximum power consumptionApprox. 100 W
Operating temperature6362D: 0 °C – 40 °C 6362C: 5 °C – 35 °C Specified performance: 18 °C – 28 °C
Warm-up time (6362D)At least 1 h, followed by internal source calibration

† Value from the SeaGOAT catalog. Manufacturer confirmation pending.

Overview

The 6362 series is a family of grating-based benchtop optical spectrum analyzers built for high resolution, wide dynamic range and fast sweeps. The 6362D covers 600 nm – 1700 nm and the 6362C covers 350 nm – 1200 nm; the SeaGOAT catalog also lists the 6362E (1200 nm – 2400 nm) and 6362EA (1000 nm – 2500 nm).

Resolution bandwidth can be set from 0.02 nm to 2 nm, with a minimum sampling resolution of 0.001 nm. On the 6362D, dynamic range reaches 73 dB (0.05 nm resolution, ±1.0 nm from the peak) and sensitivity reaches -90 dBm between 1300 nm and 1620 nm.

Built-in analysis routines evaluate single-longitudinal-mode lasers such as DFB-LDs (threshold and side-mode suppression ratio), multi-mode lasers such as FP-LDs (n dB loss, envelope and RMS methods), LEDs and LD modules, plus WDM, optical amplifier, WDM filter and fiber PMD applications. A 12.1-inch touch screen, USB and Ethernet are standard; GPIB and trigger I/O are available as an option.

Applications

  • DWDM system and optical amplifier testing
  • Characterization of LEDs, FP-LDs, DFB-LDs and optical transceivers
  • Passive component testing, including fibers and fiber Bragg gratings
  • Spectral testing of optical chips, optical modules and opto-electronic systems

Available models

Specifications differ between models. Select a model to include it in your inquiry.

ModelRangeModel-specific valuesContact Sales
6362C350 – 1200 nm
Wavelength accuracy:
±0.200 nm
Sensitivity (HIGH3):
-60 dBm
Dynamic range:
60 dB (633 nm, peak ±0.5 nm, 0.02 nm resolution)
6362D600 – 1700 nm
Wavelength accuracy:
±0.02 nm (1520 nm – 1620 nm)
Sensitivity (HIGH3):
-90 dBm (1300 nm – 1620 nm)
Dynamic range:
73 dB (0.05 nm resolution, peak ±1.0 nm)
6362E1200 – 2400 nm1200 nm – 2400 nm
6362EA1000 – 2500 nm1000 nm – 2500 nm

Documents and datasheets

Original datasheets, manuals and application documents for this equipment are available from our sales team.

  • Brochure · ZH
Request the datasheet

Request a quote for the 6362C/D/E/EA

Tell us your requirements and our sales team will reply with configuration options and a written quotation. The exact model number is included automatically. No prices or online ordering on this site.

Buying for a facility in the United States or Canada? How quotations, shipping and import documents work

We use your details only to answer this inquiry. No newsletters.

Specifications are compiled from the manufacturer’s official product information and the SeaGOAT catalog. Last verified November 17, 2026. Specifications may change; please confirm the exact configuration with our sales team before ordering. Partially verified against manufacturer data.

6317A tunable laser source, front view
Opto-Electronic Test InstrumentsBenchtop

6317A Tunable Laser Source

6317A

Mode-hop-free Littman external-cavity tunable laser for 1500 nm – 1600 nm (extendable to 1480 nm – 1680 nm), with ±5 pm absolute accuracy and sweeps up to 240 nm/s.

Wavelength
1480 – 1680 nm
Max. output
+13 dBm
View details
6433F lightwave component analyzer with optical test unit, front view
Opto-Electronic Test InstrumentsBenchtop

6433 Series Lightwave Component Analyzer

6433D/F/H/L/N/P · 6 models

Lightwave component analyzers combining a VNA with optical transmitter and receiver modules for E/E, E/O, O/E and O/O measurements from 10 MHz up to 110 GHz.

Frequency
10 MHz – 110 GHz
View details