Skip to content
SeaGOAT Electronics logo
4025 series handheld spectrum analyzer, front three-quarter view (4025D shown)
Handheld RF & Microwave AnalyzersHandheld

4025 Series Handheld Spectrum Analyzer

Model
4025A/B/D/E/G/K
Supplied by
SeaGOAT Electronics
Frequency
9 kHz – 54 GHz

New-generation handheld spectrum analyzer, 9 kHz up to 54 GHz in six models, with -165 dBm/Hz typical DANL, optional 120 MHz real-time analysis and 5G NR demodulation.

Key highlights

  • Six models from 9 kHz – 6 GHz up to 9 kHz – 54 GHz, full-band preamplifier standard
  • DANL of -165 dBm/Hz typical (4025A/B/D, 2 MHz – 2 GHz, preamplifier on)
  • SSB phase noise of -113 dBc/Hz typical at 100 kHz offset, 1 GHz carrier
  • Optional 40 MHz or 120 MHz real-time spectrum analysis
  • Sweep time under 33 ms for a 20 GHz span
  • -20 °C to +55 °C operation, 3.5 – 3.8 kg with battery

Supplied by SeaGOAT Electronics, an independent international supplier of electronic test and measurement equipment. SeaGOAT Electronics does not manufacture this equipment; it is sourced through our manufacturing and supply partners.

Specifications

Frequency
Frequency range9 kHz – 54 GHz (by model); low end extendable to 5 kHz
Reference aging±5 × 10⁻⁷ / year
Reference accuracy after GPS locking (typ.)±10 ppb
Resolution bandwidth (RBW)1 Hz – 20 MHz (1-2-3-5-8 steps)
Video bandwidth (VBW)1 Hz – 20 MHz (1-2-3-5-8 steps)
Phase noise
SSB phase noise, 1 GHz carrier, 10 kHz offset≤ -108 dBc/Hz
SSB phase noise, 1 GHz carrier, 100 kHz offset≤ -110 dBc/Hz
SSB phase noise, 1 GHz carrier, 100 kHz offset (typ.)≤ -113 dBc/Hz
SSB phase noise, 10 GHz carrier, 100 kHz offset (typ.)≤ -108 dBc/Hz
SSB phase noise, 1 GHz carrier, 1 MHz offset≤ -118 dBc/Hz
SSB phase noise, 1 GHz carrier, 10 MHz offset≤ -129 dBc/Hz
Amplitude and sensitivity
Third-order intercept (TOI), 50 MHz – 54 GHz≥ +13 dBm
Third-order intercept (TOI) at 900 MHz (typ.)+16 dBm
Second harmonic distortion, 50 MHz – 27 GHz≤ -70 dBc
Total amplitude uncertainty (typ.)±1.0 dB
Input attenuator0 – 30 dB, 2 dB steps
Reference level range-150 dBm – +30 dBm
Sweep and display
Sweep time, 20 GHz span, 3 MHz RBW< 33 ms
Sweep time, 1 GHz span, 1 kHz RBW, fast FFT mode< 4 s
Zero-span sweep time1 µs – 6000 s
Real-time analysis bandwidth (options)40 MHz (S12), 120 MHz (H37)
Display10.1-inch capacitive touch screen; 3 traces, 6 markers, 6 detectors
Measurement functions
Optional measurement modesInterference analyzer, channel scanner, field strength, USB CW and peak power meter, AM/FM/PM analyzer, location analyzer, indoor/outdoor map, gated sweep, IQ analyzer, GSM/EDGE, LTE and 5G NR demodulation, vector signal analysis, EMI analysis, phase noise
Interfaces
Other interfaces10 MHz reference in/out, external trigger in, GPS antenna (option), IF output (option), Wi-Fi antenna (option), all SMA female; LAN (RJ-45), USB 3.0 / USB-C, 3.5 mm audio, Micro SD
General
Dimensions (W × H × D)316.5 × 236.5 × 75 mm (without strap and connectors, rear stand closed)
Power supplyAC adapter 100 – 240 V AC, 50/60 Hz (19 V DC, 4.7 A output); 10.8 V lithium-ion battery
Operating temperature-20 °C – +55 °C
Storage temperature-50 °C – +70 °C

Overview

The 4025 is a new-generation high-performance handheld spectrum analyzer. Six models cover 9 kHz up to 6, 9, 20, 26.5, 44 or 54 GHz (the low end can be extended to 5 kHz), and every model includes a full-band preamplifier. It is designed for installation, commissioning, maintenance and interference hunting on wireless equipment in the field.

Typical performance includes -165 dBm/Hz DANL (4025A/B/D) or -163 dBm/Hz (4025E/G/K) with the preamplifier on, -113 dBc/Hz phase noise at 100 kHz offset from 1 GHz, +16 dBm TOI at 900 MHz and ±1.0 dB total amplitude uncertainty. A 20 GHz span sweeps in under 33 ms.

Optional modes add real-time spectrum analysis (40 MHz or 120 MHz), interference and location analysis, channel scanning, field strength, USB CW and peak power measurement, AM/FM/PM analysis, GSM/EDGE, LTE and 5G NR demodulation, I/Q and vector signal analysis, EMI scanning, phase noise and gated sweep. The 10.1-inch touch screen, -20 °C to +55 °C operating range and 3 – 4 hour battery life suit outdoor work.

Applications

  • Field installation, commissioning and maintenance of radar, communication and electronic warfare equipment
  • Field testing and diagnosis of transmitters and receivers
  • Broadband spectrum monitoring and interference identification
  • Interference source direction finding and map positioning
  • Testing of TDMA and transient time-varying signals with gated sweep and real-time analysis

Available models

Specifications differ between models. Select a model to include it in your inquiry.

ModelRangeModel-specific valuesContact Sales
4025A9 kHz – 6 GHz
DANL, 2 MHz – 2 GHz, preamplifier on (typ.):
-165 dBm/Hz
DANL, preamplifier on (normalized to 1 Hz):
≤ -161 dBm (2 MHz – 2.4 GHz) ≤ -160 dBm (2.4 – 6 GHz) ≤ -159 dBm (6 – 9 GHz) ≤ -158 dBm (9 – 14 GHz) ≤ -156 dBm (14 – 20 GHz)
Absolute amplitude accuracy:
±1.00 dB (10 MHz – 20 GHz)
Maximum input power (CW, ≥ 50 MHz):
+27 dBm
RF input connector:
Type N (female)
Weight:
3.0 kg without battery, 3.5 kg with battery (typ.)
Battery operating time (typ., spectrum analyzer mode):
4 h
Power consumption (typ., spectrum analyzer mode):
22 – 28 W
4025B9 kHz – 9 GHz
DANL, 2 MHz – 2 GHz, preamplifier on (typ.):
-165 dBm/Hz
DANL, preamplifier on (normalized to 1 Hz):
≤ -161 dBm (2 MHz – 2.4 GHz) ≤ -160 dBm (2.4 – 6 GHz) ≤ -159 dBm (6 – 9 GHz) ≤ -158 dBm (9 – 14 GHz) ≤ -156 dBm (14 – 20 GHz)
Absolute amplitude accuracy:
±1.00 dB (10 MHz – 20 GHz)
Maximum input power (CW, ≥ 50 MHz):
+27 dBm
RF input connector:
Type N (female)
Weight:
3.0 kg without battery, 3.5 kg with battery (typ.)
Battery operating time (typ., spectrum analyzer mode):
4 h
Power consumption (typ., spectrum analyzer mode):
22 – 28 W
4025D9 kHz – 20 GHz
DANL, 2 MHz – 2 GHz, preamplifier on (typ.):
-165 dBm/Hz
DANL, preamplifier on (normalized to 1 Hz):
≤ -161 dBm (2 MHz – 2.4 GHz) ≤ -160 dBm (2.4 – 6 GHz) ≤ -159 dBm (6 – 9 GHz) ≤ -158 dBm (9 – 14 GHz) ≤ -156 dBm (14 – 20 GHz)
Absolute amplitude accuracy:
±1.30 dB (10 MHz – 20 GHz)
Maximum input power (CW, ≥ 50 MHz):
+27 dBm
RF input connector:
Type N (female)
Weight:
3.0 kg without battery, 3.5 kg with battery (typ.)
Battery operating time (typ., spectrum analyzer mode):
4 h
Power consumption (typ., spectrum analyzer mode):
22 – 28 W
4025E9 kHz – 26.5 GHz
DANL, 2 MHz – 2 GHz, preamplifier on (typ.):
-163 dBm/Hz
DANL, preamplifier on (normalized to 1 Hz):
≤ -159 dBm (2 MHz – 9 GHz) ≤ -156 dBm (9 – 14 GHz) ≤ -154 dBm (14 – 32 GHz) ≤ -152 dBm (32 – 40 GHz) ≤ -148 dBm (40 – 44 GHz) ≤ -145 dBm (44 – 50 GHz) ≤ -140 dBm (50 – 54 GHz)
Absolute amplitude accuracy:
±1.00 dB (10 MHz – 20 GHz) ±1.40 dB (20 – 44 GHz)
Maximum input power (CW, ≥ 50 MHz):
+25 dBm
RF input connector:
3.5 mm (male)
Weight:
3.3 kg without battery, 3.8 kg with battery (typ.)
Battery operating time (typ., spectrum analyzer mode):
3 h
Power consumption (typ., spectrum analyzer mode):
26 – 33 W
4025G9 kHz – 44 GHz
DANL, 2 MHz – 2 GHz, preamplifier on (typ.):
-163 dBm/Hz
DANL, preamplifier on (normalized to 1 Hz):
≤ -159 dBm (2 MHz – 9 GHz) ≤ -156 dBm (9 – 14 GHz) ≤ -154 dBm (14 – 32 GHz) ≤ -152 dBm (32 – 40 GHz) ≤ -148 dBm (40 – 44 GHz) ≤ -145 dBm (44 – 50 GHz) ≤ -140 dBm (50 – 54 GHz)
Absolute amplitude accuracy:
±1.00 dB (10 MHz – 20 GHz) ±1.40 dB (20 – 44 GHz)
Maximum input power (CW, ≥ 50 MHz):
+25 dBm
RF input connector:
2.4 mm (male)
Weight:
3.3 kg without battery, 3.8 kg with battery (typ.)
Battery operating time (typ., spectrum analyzer mode):
3 h
Power consumption (typ., spectrum analyzer mode):
26 – 33 W
4025K9 kHz – 54 GHz
DANL, 2 MHz – 2 GHz, preamplifier on (typ.):
-163 dBm/Hz
DANL, preamplifier on (normalized to 1 Hz):
≤ -159 dBm (2 MHz – 9 GHz) ≤ -156 dBm (9 – 14 GHz) ≤ -154 dBm (14 – 32 GHz) ≤ -152 dBm (32 – 40 GHz) ≤ -148 dBm (40 – 44 GHz) ≤ -145 dBm (44 – 50 GHz) ≤ -140 dBm (50 – 54 GHz)
Absolute amplitude accuracy:
±1.00 dB (10 MHz – 20 GHz) ±1.40 dB (20 – 44 GHz) ±1.80 dB (44 – 54 GHz)
Maximum input power (CW, ≥ 50 MHz):
+25 dBm
RF input connector:
2.4 mm (male)
Weight:
3.3 kg without battery, 3.8 kg with battery (typ.)
Battery operating time (typ., spectrum analyzer mode):
3 h
Power consumption (typ., spectrum analyzer mode):
26 – 33 W

Documents and datasheets

Original datasheets, manuals and application documents for this equipment are available from our sales team.

  • Datasheet · EN
  • User manual · EN
  • Quick start guide · EN
  • Programming manual · EN
Request the datasheet

Request a quote for the 4025A/B/D/E/G/K

Tell us your requirements and our sales team will reply with configuration options and a written quotation. The exact model number is included automatically. No prices or online ordering on this site.

Buying for a facility in the United States or Canada? How quotations, shipping and import documents work

We use your details only to answer this inquiry. No newsletters.

Specifications are compiled from the manufacturer’s official product information and the SeaGOAT catalog. Last verified November 17, 2026. Specifications may change; please confirm the exact configuration with our sales team before ordering. Verified against manufacturer data.

4024 series handheld spectrum analyzer, front three-quarter view
Handheld RF & Microwave AnalyzersHandheld

4024 Series Handheld Spectrum Analyzer

4024A/B/C/D/E/F/G/H/L · 9 models

Battery-powered handheld spectrum analyzer in nine models from 9 kHz up to 67 GHz, with standard full-band preamplifier and -163 dBm/Hz typical DANL.

Frequency
9 kHz – 67 GHz
View details
4024CA handheld real-time spectrum analyzer, front view
Handheld RF & Microwave AnalyzersHandheld

4024CA Handheld Real-Time Spectrum Analyzer

4024CA

Handheld 9 kHz – 9 GHz real-time spectrum analyzer with 120 MHz real-time bandwidth and 5G NR, LTE FDD/TDD and GSM/EDGE demodulation for field work.

Frequency
9 kHz – 9 GHz
Real-time BW
120 MHz
View details
4042 series spectrum analyzer, front view (4042D shown)
Signal & Spectrum AnalyzersPortable

4042 Series Spectrum Analyzer

4042B/D · 2 models

Portable 9 kHz – 20 GHz spectrum analyzer under 6.5 kg with standard full-band preamplifier, -163 dBm/Hz typical DANL and optional 40 MHz real-time analysis.

Frequency
9 kHz – 20 GHz
Real-time BW
40 MHz
View details
4959 series handheld microwave analyzer, front three-quarter view (4959K shown)
Handheld RF & Microwave AnalyzersHandheld

4959 Series Handheld Microwave Analyzer

4959B/D/E/G/H/K · 6 models

Handheld microwave analyzer covering 9 kHz/300 kHz up to 54 GHz with spectrum analysis and dual-port vector network analysis, plus cable and antenna test options.

Frequency
9 kHz – 54 GHz
Real-time BW
40 MHz
View details
Request a Quote