Skip to content
SeaGOAT Electronics logo
4024 series handheld spectrum analyzer, front three-quarter view
Handheld RF & Microwave AnalyzersHandheld

4024 Series Handheld Spectrum Analyzer

Model
4024A/B/C/D/E/F/G/H/L
Supplied by
SeaGOAT Electronics
Frequency
9 kHz – 67 GHz

Battery-powered handheld spectrum analyzer in nine models from 9 kHz up to 67 GHz, with standard full-band preamplifier and -163 dBm/Hz typical DANL.

Key highlights

  • Nine models from 9 kHz – 4 GHz up to 9 kHz – 67 GHz
  • DANL of -163 dBm/Hz typical with standard full-band preamplifier
  • SSB phase noise of -112 dBc/Hz (4024A/B/C) and -106 dBc/Hz (4024D–L) at 100 kHz offset, 1 GHz carrier
  • Sweep time under 20 ms for a 1 GHz span
  • Battery or adapter power, -10 °C to +50 °C operation

Supplied by SeaGOAT Electronics, an independent international supplier of electronic test and measurement equipment. SeaGOAT Electronics does not manufacture this equipment; it is sourced through our manufacturing and supply partners.

Specifications

Frequency
Frequency range9 kHz – 67 GHz (by model)
Tuning resolution1 Hz
Reference aging±0.5 ppm / year
Resolution bandwidth (RBW)1 Hz – 10 MHz (1-3 steps)
Video bandwidth (VBW)1 Hz – 10 MHz (1-3 steps)
Amplitude and sensitivity
DANL, 1 Hz RBW (typ.)-163 dBm
PreamplifierFull band, standard
Absolute amplitude accuracy±1.8 dB (10 MHz – 13 GHz) ±2.3 dB (13 – 40 GHz) ±2.7 dB (40 – 50 GHz) ±3.0 dB (50 – 67 GHz)
Reference level range-120 dBm – +30 dBm
Phase noise
SSB phase noise, 1 GHz carrier, 100 kHz offset (4024A/B/C)≤ -112 dBc/Hz
SSB phase noise, 1 GHz carrier, 100 kHz offset (4024D/E/F/G/H/L)≤ -106 dBc/Hz
Sweep and display
Shortest sweep time, 1 GHz span< 20 ms
Zero-span sweep time10 µs – 600 s
Display8.4-inch LCD with capacitive touch screen
Measurement functions
Measurement modesSpectrum analyzer, interference analyzer (spectrogram, RSSI), AM/FM/PM analyzer, channel scanner, power meter, signal analyzer
Smart measurementsField strength, channel power, occupied bandwidth, ACPR, tune and listen, C/N, emission mask
Interfaces
Other interfaces10 MHz reference in/out, external trigger in, IF output, GPS antenna input (all BNC female)
General
Dimensions (W × H × D)314 × 218 × 91 mm (without handle and stand)
Operating temperature-10 °C – +50 °C (battery operation 0 °C – +45 °C)
Storage temperature-40 °C – +70 °C
Power supplyInternal battery or adapter

Overview

The 4024 series is a compact, lightweight handheld spectrum analyzer for field work. Nine models cover 9 kHz up to 4, 6.5, 9, 20, 26.5, 32, 44, 50 or 67 GHz, every model includes a full-band preamplifier, and the instrument runs from its internal battery or an adapter over a -10 °C to +50 °C operating range.

It offers low displayed average noise level (-163 dBm/Hz typical), low phase noise and fast sweeps (under 20 ms for a 1 GHz span). Measurement modes include spectrum analysis, interference analysis with spectrogram and RSSI, AM/FM/PM analysis, power meter and channel scanner, plus one-button channel power, occupied bandwidth, ACPR, tune and listen, emission mask, C/N and field strength measurements.

An 8.4-inch LCD with integrated capacitive touch screen, a 10 MHz reference input/output, GPS antenna input, zero-span IF output and external trigger input support installation, maintenance and monitoring tasks in the field.

Applications

  • Field installation, calibration, repair and maintenance of communication and electronic equipment
  • Transmitter and receiver field testing and diagnosis
  • Electromagnetic environment monitoring and spectrum surveillance with external antennas
  • Radio interference analysis and identification of illegal transmissions
  • Microwave, satellite and radar system maintenance

Available models

Specifications differ between models. Select a model to include it in your inquiry.

ModelRangeModel-specific valuesContact Sales
4024A9 kHz – 4 GHz
SSB phase noise, 1 GHz carrier:
≤ -108 dBc/Hz (10 kHz) ≤ -112 dBc/Hz (100 kHz) ≤ -118 dBc/Hz (1 MHz) ≤ -129 dBc/Hz (10 MHz)
DANL, preamplifier on (normalized to 1 Hz):
≤ -160 dBm (10 MHz – 3 GHz) ≤ -157 dBm (3 – 9 GHz)
Weight:
≤ 4.5 kg
Battery operating time:
About 3 h
Power consumption:
≤ 25 W
RF input connector:
Type N (female)
Input attenuator:
0 – 30 dB, 5 dB steps
Maximum continuous input, ≥ 10 dB attenuation (peak, typ.):
+27 dBm
4024B9 kHz – 6.5 GHz
SSB phase noise, 1 GHz carrier:
≤ -108 dBc/Hz (10 kHz) ≤ -112 dBc/Hz (100 kHz) ≤ -118 dBc/Hz (1 MHz) ≤ -129 dBc/Hz (10 MHz)
DANL, preamplifier on (normalized to 1 Hz):
≤ -160 dBm (10 MHz – 3 GHz) ≤ -157 dBm (3 – 9 GHz)
Weight:
≤ 4.5 kg
Battery operating time:
About 3 h
Power consumption:
≤ 25 W
RF input connector:
Type N (female)
Input attenuator:
0 – 30 dB, 5 dB steps
Maximum continuous input, ≥ 10 dB attenuation (peak, typ.):
+27 dBm
4024C9 kHz – 9 GHz
SSB phase noise, 1 GHz carrier:
≤ -108 dBc/Hz (10 kHz) ≤ -112 dBc/Hz (100 kHz) ≤ -118 dBc/Hz (1 MHz) ≤ -129 dBc/Hz (10 MHz)
DANL, preamplifier on (normalized to 1 Hz):
≤ -160 dBm (10 MHz – 3 GHz) ≤ -157 dBm (3 – 9 GHz)
Weight:
≤ 4.5 kg
Battery operating time:
About 3 h
Power consumption:
≤ 25 W
RF input connector:
Type N (female)
Input attenuator:
0 – 30 dB, 5 dB steps
Maximum continuous input, ≥ 10 dB attenuation (peak, typ.):
+27 dBm
4024D9 kHz – 20 GHz
SSB phase noise, 1 GHz carrier:
≤ -102 dBc/Hz (10 kHz) ≤ -106 dBc/Hz (100 kHz) ≤ -111 dBc/Hz (1 MHz) ≤ -123 dBc/Hz (10 MHz)
DANL, preamplifier on (normalized to 1 Hz):
≤ -157 dBm (10 MHz – 20 GHz) ≤ -154 dBm (20 – 32 GHz) ≤ -148 dBm (32 – 40 GHz)
Weight:
≤ 5.1 kg
Battery operating time:
About 2.5 h
Power consumption:
≤ 33 W
RF input connector:
Type N (female)
Input attenuator:
0 – 50 dB, 10 dB steps
Maximum continuous input, ≥ 10 dB attenuation (peak, typ.):
+30 dBm
4024E9 kHz – 26.5 GHz
SSB phase noise, 1 GHz carrier:
≤ -102 dBc/Hz (10 kHz) ≤ -106 dBc/Hz (100 kHz) ≤ -111 dBc/Hz (1 MHz) ≤ -123 dBc/Hz (10 MHz)
DANL, preamplifier on (normalized to 1 Hz):
≤ -157 dBm (10 MHz – 20 GHz) ≤ -154 dBm (20 – 32 GHz) ≤ -148 dBm (32 – 40 GHz)
Weight:
≤ 5.1 kg
Battery operating time:
About 2.5 h
Power consumption:
≤ 33 W
RF input connector:
Type N (female)
Input attenuator:
0 – 50 dB, 10 dB steps
Maximum continuous input, ≥ 10 dB attenuation (peak, typ.):
+30 dBm
4024F9 kHz – 32 GHz
SSB phase noise, 1 GHz carrier:
≤ -102 dBc/Hz (10 kHz) ≤ -106 dBc/Hz (100 kHz) ≤ -111 dBc/Hz (1 MHz) ≤ -123 dBc/Hz (10 MHz)
DANL, preamplifier on (normalized to 1 Hz):
≤ -157 dBm (10 MHz – 20 GHz) ≤ -154 dBm (20 – 32 GHz) ≤ -148 dBm (32 – 40 GHz)
Weight:
≤ 5.1 kg
Battery operating time:
About 2.5 h
Power consumption:
≤ 33 W
RF input connector:
2.4 mm (male)
Input attenuator:
0 – 50 dB, 10 dB steps
Maximum continuous input, ≥ 10 dB attenuation (peak, typ.):
+30 dBm
4024G9 kHz – 44 GHz
SSB phase noise, 1 GHz carrier:
≤ -102 dBc/Hz (10 kHz) ≤ -106 dBc/Hz (100 kHz) ≤ -111 dBc/Hz (1 MHz) ≤ -123 dBc/Hz (10 MHz)
DANL, preamplifier on (normalized to 1 Hz):
≤ -157 dBm (10 MHz – 20 GHz) ≤ -154 dBm (20 – 32 GHz) ≤ -148 dBm (32 – 40 GHz)
Weight:
≤ 5.1 kg
Battery operating time:
About 2.5 h
Power consumption:
≤ 33 W
RF input connector:
2.4 mm (male)
Input attenuator:
0 – 50 dB, 10 dB steps
Maximum continuous input, ≥ 10 dB attenuation (peak, typ.):
+30 dBm
4024H9 kHz – 50 GHz
SSB phase noise, 1 GHz carrier:
≤ -102 dBc/Hz (10 kHz) ≤ -106 dBc/Hz (100 kHz) ≤ -111 dBc/Hz (1 MHz) ≤ -123 dBc/Hz (10 MHz)
DANL, preamplifier on (normalized to 1 Hz):
≤ -153 dBm (10 MHz – 20 GHz) ≤ -152 dBm (20 – 32 GHz) ≤ -147 dBm (32 – 40 GHz) ≤ -142 dBm (40 – 46 GHz) ≤ -132 dBm (46 – 60 GHz) ≤ -118 dBm (60 – 67 GHz)
Weight:
≤ 5.3 kg
Battery operating time:
2 h (typ.)
Power consumption:
≤ 38 W
RF input connector:
1.85 mm (male)
Input attenuator:
0 – 30 dB, 5 dB steps
Maximum continuous input, ≥ 10 dB attenuation (peak, typ.):
+27 dBm
4024L9 kHz – 67 GHz
SSB phase noise, 1 GHz carrier:
≤ -102 dBc/Hz (10 kHz) ≤ -106 dBc/Hz (100 kHz) ≤ -111 dBc/Hz (1 MHz) ≤ -123 dBc/Hz (10 MHz)
DANL, preamplifier on (normalized to 1 Hz):
≤ -153 dBm (10 MHz – 20 GHz) ≤ -152 dBm (20 – 32 GHz) ≤ -147 dBm (32 – 40 GHz) ≤ -142 dBm (40 – 46 GHz) ≤ -132 dBm (46 – 60 GHz) ≤ -118 dBm (60 – 67 GHz)
Weight:
≤ 5.3 kg
Battery operating time:
2 h (typ.)
Power consumption:
≤ 38 W
RF input connector:
1.85 mm (male)
Input attenuator:
0 – 30 dB, 5 dB steps
Maximum continuous input, ≥ 10 dB attenuation (peak, typ.):
+27 dBm

Documents and datasheets

Original datasheets, manuals and application documents for this equipment are available from our sales team.

  • Datasheet · EN
  • User manual · EN
  • Programming manual · EN
Request the datasheet

Request a quote for the 4024A/B/C/D/E/F/G/H/L

Tell us your requirements and our sales team will reply with configuration options and a written quotation. The exact model number is included automatically. No prices or online ordering on this site.

Buying for a facility in the United States or Canada? How quotations, shipping and import documents work

We use your details only to answer this inquiry. No newsletters.

Specifications are compiled from the manufacturer’s official product information and the SeaGOAT catalog. Last verified November 17, 2026. Specifications may change; please confirm the exact configuration with our sales team before ordering. Verified against manufacturer data.

4024CA handheld real-time spectrum analyzer, front view
Handheld RF & Microwave AnalyzersHandheld

4024CA Handheld Real-Time Spectrum Analyzer

4024CA

Handheld 9 kHz – 9 GHz real-time spectrum analyzer with 120 MHz real-time bandwidth and 5G NR, LTE FDD/TDD and GSM/EDGE demodulation for field work.

Frequency
9 kHz – 9 GHz
Real-time BW
120 MHz
View details
4025 series handheld spectrum analyzer, front three-quarter view (4025D shown)
Handheld RF & Microwave AnalyzersHandheld

4025 Series Handheld Spectrum Analyzer

4025A/B/D/E/G/K · 6 models

New-generation handheld spectrum analyzer, 9 kHz up to 54 GHz in six models, with -165 dBm/Hz typical DANL, optional 120 MHz real-time analysis and 5G NR demodulation.

Frequency
9 kHz – 54 GHz
Real-time BW
120 MHz
View details
4042 series spectrum analyzer, front view (4042D shown)
Signal & Spectrum AnalyzersPortable

4042 Series Spectrum Analyzer

4042B/D · 2 models

Portable 9 kHz – 20 GHz spectrum analyzer under 6.5 kg with standard full-band preamplifier, -163 dBm/Hz typical DANL and optional 40 MHz real-time analysis.

Frequency
9 kHz – 20 GHz
Real-time BW
40 MHz
View details
Request a Quote