Skip to content
SeaGOAT Electronics logo
3916 series EMI test receiver, front view (3916H shown)
EMI & Monitoring ReceiversBenchtop

3916 Series EMI Test Receiver

Model
3916B/D/E/F/H
Supplied by
SeaGOAT Electronics
Frequency
50 GHz

Compliance-grade EMI test receiver up to 8.4, 18, 26.5, 45 or 50 GHz for GB/T 6113, GJB 151 and CISPR testing, with FFT time-domain scan and 400 MHz real-time analysis.

Key highlights

  • Five models with upper limits of 8.4, 18, 26.5, 45 and 50 GHz
  • CISPR-compliant detectors and EMI filters from 1 Hz to 10 MHz (-6 dB)
  • FFT time-domain scan with up to 390 MHz parallel processing bandwidth
  • Real-time spectrum analysis up to 400 MHz with 0.31 µs minimum duration for 100% POI
  • Absolute amplitude uncertainty ≤ 0.2 dB at the 500 MHz calibration point

Supplied by SeaGOAT Electronics, an independent international supplier of electronic test and measurement equipment. SeaGOAT Electronics does not manufacture this equipment; it is sourced through our manufacturing and supply partners.

Specifications

Frequency
Upper frequency limit8.4, 18, 26.5, 45 or 50 GHz (by model)
Frequency range, input 1, AC coupled10 MHz to the model's upper limit
Frequency range, input 2, AC coupled9 kHz – 1 GHz
Frequency resolution0.1 Hz
Reference aging rate±3 × 10⁻⁸ / year; ±2 × 10⁻⁸ / year (option 3916-H13)
Preselector sections23 (including notch filter)
Sweep time3 µs – 16000 s (span ≥ 10 Hz); 1 µs – 16000 s (zero span)
Dwell time50 µs – 100 s
EMI measurement
EMI filters (-6 dB bandwidth)1 Hz, 10 Hz, 100 Hz, 200 Hz, 1 kHz, 9 kHz, 10 kHz, 100 kHz, 120 kHz, 1 MHz, 10 MHz
Standard filters (-3 dB RBW)1 Hz – 3 MHz (1-2-3-5 steps); 4, 5, 6, 8, 10, 20 MHz
Video bandwidth (VBW)1 Hz – 20 MHz (1-2-3-5 steps, nominal)
DetectorsMax peak, min peak, RMS, quasi-peak, average, CISPR average, CISPR RMS (up to seven simultaneously)
Supported EMC standardsGB/T 6113, GJB 151, CISPR
APD measurement200 Hz, 9 kHz, 120 kHz, 1 MHz bandwidths; minimum probability 10⁻⁷; maximum time 120 s
FFT time-domain scan and real-time analysis
FFT time-domain bandwidth29.8 MHz (standard), 390 MHz (option)
FFT points (parallel filtering and detection)Up to 16384
FFT overlap> 93.75 %
FFT amplitude error≤ 0.4 dB
Real-time analysis bandwidth40 MHz, 200 MHz, 400 MHz
Minimum signal duration for 100% POI0.31 µs
Phase noise
SSB phase noise, 1 GHz carrier, 100 Hz offset< -107 dBc/Hz
SSB phase noise, 1 GHz carrier, 1 kHz offset< -125 dBc/Hz
SSB phase noise, 1 GHz carrier, 10 kHz offset< -133 dBc/Hz
SSB phase noise, 1 GHz carrier, 100 kHz offset< -135 dBc/Hz
Amplitude and sensitivity
DANL at 1 GHz (typ.)-153 dBm/Hz† Value from the SeaGOAT catalog. Manufacturer confirmation pending.
DANL at 1 GHz, preamplifier on (typ.)-160 dBm/Hz† Value from the SeaGOAT catalog. Manufacturer confirmation pending.
DANL, preselector and preamplifier on, without LNA option (normalized to 1 Hz)≤ -151 dBm (10 – 100 MHz) ≤ -155 dBm (100 MHz – 2.2 GHz) ≤ -154 dBm (2.2 – 3.25 GHz) ≤ -152 dBm (3.25 – 5.25 GHz) ≤ -153 dBm (5.25 – 6.5 GHz) ≤ -151 dBm (6.5 – 8.2 GHz) ≤ -141 dBm (8.2 – 26.5 GHz) ≤ -137 dBm (26.5 – 40 GHz) ≤ -132 dBm (40 – 50 GHz)
DANL, low-noise amplifier on, preselector off (option 3916-H34, normalized to 1 Hz)≤ -155 dBm (10 – 100 MHz) ≤ -160 dBm (100 MHz – 1.2 GHz) ≤ -159 dBm (1.2 – 3.25 GHz) ≤ -157 dBm (3.25 – 5.25 GHz) ≤ -156 dBm (5.25 – 18 GHz) ≤ -154 dBm (18 – 26.5 GHz) ≤ -153 dBm (26.5 – 40 GHz) ≤ -148 dBm (40 – 50 GHz)
Absolute amplitude uncertainty (500 MHz calibration point)≤ 0.2 dB
Third-order intercept (preselector, preamplifier and LNA off)≥ +20 dBm (10 – 100 MHz) ≥ +18 dBm (100 MHz – 3.25 GHz) ≥ +20 dBm (3.25 – 8.2 GHz) ≥ +18 dBm (8.2 – 50 GHz)
Image rejection≥ 80 dBc
Maximum CW input level (preselector and preamplifier off, attenuation ≥ 20 dB)+30 dBm
Input attenuator0 – 70 dB, 2 dB steps
Input VSWR, input 1 (attenuation ≥ 10 dB)≤ 1.2 (9 kHz – 1 GHz) ≤ 1.5 (1 – 8 GHz) ≤ 1.8 (8 – 45 GHz) ≤ 2.0 (45 – 50 GHz)
Interfaces
RF inputsInput 1 (model-dependent connector); input 2 Type N (female) with surge protection
Communication interfacesUSB (3 front, 3 rear), LAN 10/100/1000, GPIB (IEEE-488), DisplayPort, 3.5 mm headphone
Other interfacesLO output and IF input for frequency extension; reference inputs/outputs; 2 trigger inputs and 2 trigger outputs (BNC)
General
Dimensions (W × H × D)426 × 221.5 × 450 mm (without handles and feet)
Maximum weight35 kg (depends on options)
Power supply100 – 240 V AC, 50 – 60 Hz
Maximum power consumption600 W
Operating temperature0 °C – +50 °C
Storage temperature-40 °C – +70 °C

† Value from the SeaGOAT catalog. Manufacturer confirmation pending.

Overview

The 3916 series is a high-performance, compliance-grade EMI test receiver developed for the GB/T 6113, GJB 151 and CISPR families of electromagnetic compatibility standards. Five models reach 8.4, 18, 26.5, 45 or 50 GHz. The receiver combines high sensitivity, accuracy, dynamic range and speed for both pre-compliance and full compliance testing, and it also works as a general-purpose high-performance spectrum analyzer for microwave and millimeter-wave signals.

A built-in preselector and preamplifier, standard-compliant detectors (up to seven measured simultaneously), built-in limit lines and automatic pass/fail evaluation support standard test procedures. FFT time-domain scanning with 29.8 MHz (standard) or 390 MHz (optional) parallel processing bandwidth shortens scan times, and APD measurement, interference diagnosis and real-time spectrum analysis at 40, 200 or 400 MHz help characterize intermittent and pulsed disturbances.

Two RF inputs are provided, the second with surge protection for conducted measurements. An LO output and IF input allow frequency-range extension, and USB, LAN, GPIB and DisplayPort interfaces plus external I/Q data recording support automated test systems.

Applications

  • Radiated and conducted emission compliance testing to GJB 151 and CISPR standards
  • EMC testing in standard anechoic chambers
  • EMC pre-compliance testing and emission diagnosis
  • General-purpose microwave and millimeter-wave spectrum analysis

Available models

Specifications differ between models. Select a model to include it in your inquiry.

ModelRangeModel-specific valuesContact Sales
3916B8.4 GHz
RF input connector:
Type N (female)
3916D18 GHz
RF input connector:
Type N (female)
3916E26.5 GHz
RF input connector:
3.5 mm (male)
3916F45 GHz
RF input connector:
2.4 mm (male)
3916H50 GHz
RF input connector:
2.4 mm (male)

Documents and datasheets

Datasheets for this product are available on request.

Request the datasheet

Request a quote for the 3916B/D/E/F/H

Tell us your requirements and our sales team will reply with configuration options and a written quotation. The exact model number is included automatically. No prices or online ordering on this site.

Buying for a facility in the United States or Canada? How quotations, shipping and import documents work

We use your details only to answer this inquiry. No newsletters.

Specifications are compiled from the manufacturer’s official product information and the SeaGOAT catalog. Last verified November 17, 2026. Specifications may change; please confirm the exact configuration with our sales team before ordering. Partially verified against manufacturer data.

3943B handheld monitoring receiver, front view
EMI & Monitoring ReceiversHandheld

3943B Handheld Monitoring Receiver

3943B

Handheld 9 kHz – 8 GHz monitoring receiver with 20 MHz analysis bandwidth, direction finding from 20 MHz to 6 GHz and three parallel processing channels.

Frequency
9 kHz – 8 GHz
Analysis BW
20 MHz
View details
4051 series signal and spectrum analyzer, front view (4051L shown)
Signal & Spectrum AnalyzersBenchtop

4051 Series Signal and Spectrum Analyzer

4051A/B/C/D/E/F/G/H/L/N · 10 models

High-performance signal and spectrum analyzer covering 3 Hz – 85 GHz in ten models, with up to 1 GHz analysis bandwidth and 4 GB capture memory.

Frequency
3 Hz – 85 GHz
Analysis BW
1 GHz
View details
4082 series signal and spectrum analyzer, front view (4082H shown)
Signal & Spectrum AnalyzersBenchtop

4082 Series Signal and Spectrum Analyzer

4082B/D/E/F/H/L/N/P · 8 models

Flagship signal and spectrum analyzer: 2 Hz – 110 GHz coaxial coverage, up to 2 GHz analysis bandwidth and 1.2 GHz real-time analysis.

Frequency
2 Hz – 110 GHz
Analysis BW
2 GHz
View details
Request a Quote